This page is part of archived documentation for openHAB 3.4. Go to the current stable version
# DanfossAirUnit Binding
This binding supports controlling and monitoring Danfoss air units (opens new window) via Ethernet connection.
# Supported Things
This binding has been tested/reported to work with the Danfoss Air w2 / a2 / a3 devices.
# Discovery
Air units in the LAN are automatically discovered via broadcast and added to the Inbox.
# Thing Configuration
These are the available configuration parameters:
host
Hostname/IP of the air unit (automatically set by discovery service)refreshInterval
Time (in seconds) between monitoring requests to the air unit. Smaller values mean more network load, typically set between a few seconds and a minute. Defaults to 10 seconds.updateUnchangedValuesEveryMillis
Minimum time between state updates sent to the event bus for a particular channel when the state of the channel didn't change. This should avoid spamming the event bus with unnecessary updates. When set to 0, all channel state are updated every time the air unit requests are sent (see refresh interval). When set to a non zero value, unchanged values are only reported after the configured timespan has passed. Changed values are always sent to the event bus. Defaults to 60.000 (one minute), so updates are sent every minute or if the state of the channel changes.
# Channels
channel | channel group | type | readable only (RO) or writable (RW) | description |
---|---|---|---|---|
current_time | main | DateTime | RO | Current time reported by the air unit. |
mode | main | String | RW | Value to control the operation mode of the air unit. One of DEMAND, PROGRAM, MANUAL and OFF |
manual_fan_step | main | Dimmer | RW | Value to control the fan step when in MANUAL mode (10 steps) |
supply_fan_speed | main | Number | RO | Current rotation of the fan supplying air to the rooms (in rpm) |
extract_fan_speed | main | Number | RO | Current rotation of the fan extracting air from the rooms (in rpm) |
supply_fan_step | main | Dimmer | RO | Current step setting of the fan supplying air to the rooms |
extract_fan_step | main | Dimmer | RO | Current step setting of the fan extracting air from the rooms |
boost | main | Switch | RW | Enables fan boost |
night_cooling | main | Switch | RW | Enables night cooling |
room_temp | temps | Number:Temperature | RO | Temperature of the air in the room of the Air Dial |
room_temp_calculated | temps | Number:Temperature | RO | Calculated Room Temperature |
outdoor_temp | temps | Number:Temperature | RO | Temperature of the air outside |
humidity | humidity | Number:Dimensionless | RO | Current relative humidity measured by the air unit |
bypass | recuperator | Switch | RW | Disables the heat exchange. Useful in summer when room temperature is above target and outside temperature is below target. |
supply_temp | recuperator | Number | RO | Temperature of air which is passed to the rooms |
extract_temp | recuperator | Number | RO | Temperature of the air as extracted from the rooms |
exhaust_temp | recuperator | Number | RO | Temperature of the air when pushed outside |
battery_life | service | Number | RO | Remaining Air Dial Battery Level (percentage) |
filter_life | service | Number | RO | Remaining life of filter until exchange is necessary (percentage) |
filter_period | service | Number | RW | Number of months between filter replacements (between 3 and 12). This value affects calculation of filter_life by the unit, and might get overwritten by Air Dial or Link CC Controller. |
# Full Example
# Things
Suppose your autodiscovered air unit is identified by the id "danfossairunit:airunit:myairunit" (see section "Discovery").
The channel will then be identified by <air unit id>:<channel group>#<channel>
You can also manually configure your air unit in case you don't want to use autodiscovery
(e. g. if you want to have a portable configuration):
Create a new file, e. g. danfoss.things
, in your things configuration folder:
Thing danfossairunit:airunit:myairunit [host="192.168.0.7",
refreshInterval=5,
updateUnchangedValuesEveryMillis=30000]
# Items
Dimmer DanfossHRV_ManualFanStep "Manual Fan Step [%s]" {channel = "danfossairunit:airunit:myairunit:main#manual_fan_step"}
Number DanfossHRV_SupplyFanSpeed "Supply Fan Speed" {channel = "danfossairunit:airunit:myairunit:main#supply_fan_speed"}
Number DanfossHRV_ExtractFanSpeed "Extract Fan Speed" {channel = "danfossairunit:airunit:myairunit:main#extract_fan_speed"}
String DanfossHRV_Mode "Operation Mode" {channel = "danfossairunit:airunit:myairunit:main#mode"}
Switch DanfossHRV_Boost "Boost" {channel = "danfossairunit:airunit:myairunit:main#boost"}
Switch DanfossHRV_Bypass "Bypass" {channel = "danfossairunit:airunit:myairunit:recuperator#bypass"}
Number:Dimensionless DanfossHRV_Humidity "Relative humidity" <humidity> { channel = "danfossairunit:airunit:myairunit:humidity#humidity" }
Number:Temperature DanfossHRV_RoomTemperature "Room air temperatuyre" <temperature> { channel = "danfossairunit:airunit:myairunit:temps#room_temp" }
Number:Temperature DanfossHRV_OutdoorTemperature "Outdoor air temperature" <temperature> { channel = "danfossairunit:airunit:myairunit:temps#outdoor_temp" }
Number:Temperature DanfossHRV_SupplyAirTemperature "Supply air temperature" <temperature> { channel = "danfossairunit:airunit:myairunit:recuperator#supply_temp" }
Number:Temperature DanfossHRV_ExtractAirTemperature "Extract air temperature" <temperature> { channel = "danfossairunit:airunit:myairunit:recuperator#extract_temp" }
Number:Temperature DanfossHRV_ExhaustAirTemperature "Exhaust air temperature" <temperature> { channel = "danfossairunit:airunit:myairunit:recuperator#exhaust_temp" }
Number DanfossHRV_RemainingFilterLife "Remaining filter life" { channel = "danfossairunit:airunit:myairunit:service#filter_life" }
Number DanfossHRV_FilterPeriod "Filter period" { channel = "danfossairunit:airunit:myairunit:service#filter_period" }
# Sitemap
sitemap danfoss label="Danfoss" {
Frame label="Control" {
Selection item=DanfossHRV_Mode mappings=[DEMAND="Demand", OFF="Off", PROGRAM="Program", MANUAL="Manual"]
Slider item=DanfossHRV_ManualFanStep step=10 visibility=[DanfossHRV_Mode=="MANUAL"]
Switch item=DanfossHRV_Bypass
Switch item=DanfossHRV_Boost
}
Frame label="Measurements" {
Text item=DanfossHRV_Humidity
Text item=DanfossHRV_RoomTemperature
Text item=DanfossHRV_OutdoorTemperature
Text item=DanfossHRV_SupplyAirTemperature
Text item=DanfossHRV_ExtractAirTemperature
Text item=DanfossHRV_ExhaustAirTemperature
}
Frame label="Fan" {
Text item=DanfossHRV_SupplyFanSpeed
Text item=DanfossHRV_ExtractFanSpeed
}
Frame label="Filter" {
Text item=DanfossHRV_RemainingFilterLife
Slider item=DanfossHRV_FilterPeriod minValue=3 maxValue=12
}
}