This page is part of archived documentation for openHAB 3.4. Go to the current stable version

# Autelis Pool Control Binding

Autelis manufactures a network enabled pool interface for many popular pool systems. See the Autelis website (opens new window) and the Autelis Command Protocol (opens new window) for more information.

This binding supports:

  • Jandy and Pentair models
  • Read circuit, auxiliary, temperature, pump, chemistry and system values
  • Control circuit, auxiliary lighting scenes, and temperature set points

# Auto Discovery

The binding will automatically discover Autelis controllers using UPnP. If found it will try and connect with the factory default username and password.

# Binding Configuration

The binding requires no special configuration

# Manual Thing Configuration

The Autelis binding requires the host, port, username and password

In the thing file, this looks e.g. like

Thing autelis:pentair:myPool [ host="192.168.1.10", port="80", user="admin", password="admin"]

or

Thing autelis:jandy:myPool [ host="192.168.1.10", port="80", user="admin", password="admin"]

# Channels

# Pentair

Pentair devices support the following channels:

Channel Type ID Item Type
system-runstate Number
system-model Number
system-haddr Number
system-opmode Number
system-freeze Number
system-sensor1 Number
system-sensor2 Number
system-sensor3 Number
system-sensor4 Number
system-sensor5 Number
system-version String
system-time Number
equipment-circuit1 Switch
equipment-circuit2 Switch
equipment-circuit3 Switch
equipment-circuit4 Switch
equipment-circuit5 Switch
equipment-circuit6 Switch
equipment-circuit7 Switch
equipment-circuit8 Switch
equipment-circuit9 Switch
equipment-circuit10 Switch
equipment-feature1 Number
equipment-feature2 Number
equipment-feature3 Number
equipment-feature4 Number
equipment-feature5 Number
equipment-feature6 Number
equipment-feature7 Number
equipment-feature8 Number
equipment-feature9 Number
equipment-feature10 Number
temp-poolht Number
temp-spaht Number
temp-htstatus Number
temp-poolsp Number
temp-spasp Number
temp-pooltemp Number
temp-spatemp Number
temp-airtemp Number
temp-soltemp Number
temp-tempunits String
temp-htpump Number
pump-pump1 String
pump-pump2 String
pump-pump3 String
pump-pump4 String
pump-pump5 String
pump-pump6 String
pump-pump7 String
pump-pump8 String
chlor-chloren Number
chlor-poolsp Number
chlor-spasp Number
chlor-salt Number
chlor-super Number
chlor-chlorerr Number
chlor-chlorname String
lightscmd String
reboot Switch

# Jandy

Jandy devices support the following channels:

Channel Type ID Item Type
system-model Number
system-dip Number
system-opmode Number
system-vbat Number
system-lowbat Number
system-time Number
equipment-pump Number
equipment-pumplo Number
equipment-spa Number
equipment-waterfall Number
equipment-cleaner Number
equipment-poolht Number
equipment-poolht2 Number
equipment-spaht Number
equipment-solarht Number
equipment-htpmp Number
equipment-aux1 Number
equipment-aux2 Number
equipment-aux3 Number
equipment-aux4 Number
equipment-aux5 Number
equipment-aux6 Number
equipment-aux7 Number
equipment-aux8 Number
equipment-aux9 Number
equipment-aux10 Number
equipment-aux11 Number
equipment-aux12 Number
equipment-aux13 Number
equipment-aux14 Number
equipment-aux15 Number
temp-poolsp Number
temp-poolsp2 Number
temp-pooltemp Number
temp-spatemp Number
temp-airtemp Number
temp-solartemp Number
temp-tempunits String
pump-vsp1 String
pump-vsp2 String
pump-vsp3 String
pump-vsp4 String
chem-avail Number
chem-chlrp Number
chem-saltp Number
chem-chlrs Number
chem-slats Number
chem-orp1 Number
chem-orp2 Number
chem-ph1 Number
chem-ph2 Number
chem-orpfd1 Number
chem-orpfd2 Number
chem-phfd1 Number
chem-phfd2 Number
reboot Switch